PharosTM   1.7KVA Ground Fault Circuit Interrupter
Sealed all-weather unit designed and built for the U.S. Navy
Features
- Applications: marine, industrial, military, construction sites, wherever portable personnel protection is needed.
- Front panel includes Audible Alarm when input voltage is "out-of-range" plus indicator lights;
Fault Test switch, Fault Reset switch, Over-current Reset switch, and Fault indicator light.
- Operating temperature: -35 C. to + 48 C.
- All semiconductor switching. No unreliable relay contacts to arc and weld together.
- Internal isolation transformer for additional protection.
- State-of-the-art high reliability design: single point component failures either remove output
voltage or do not prevent ground fault detection.
Electrical Specifications
- Input: 115 VAC +/- 13%, 60 HZ, +/- 5%.
- Output power: 1725 VA max., continuous.
- Fault current: 5 ma., adjustable, both hot and neutral to ground.
- Over-current protection: 20 A. electronic sensing and shutdown. No fuses or circuit breakers.
- Fault trip time: < 16 millisec., relative to phase of input sine wave at time of fault.
- Input voltage spike withstand: +/- 1KV.
- Output voltage regulation: +/- 5% NL to FL.
Mechanical Specifications
- Outside dimensions: 12.5" H x 15" W x 17" L.
- Sealed top lid opens for internal access.
- Weight: 70 lbs. (approx.)
- Two lifting handles.
- Four covered output receptacles (NEMA 5-15R).
- Single input heavy duty power cable/plug.
- Internal shock isolators support electronic component shelf.
- Enclosure is NEMA 4X, stainless steel, weather resistant.
Pharos is the first in an innovative, all-electronic family of LighthouseTM series ground fault
circuit interrupters designed by Power Electronic Systems for use in applications involving
personnel use of electrical tools or lighting.
Sandy Hook15TM  and Sandy Hook20TM  GFCIs
Features
- Applications: marine, diving, fire and safety vehicles, damp environments, industrial, military, commercial,
construction sites, home use, outside or inside, anywhere portable personnel protection from faulty
hand tools or lighting is needed.
- Light weight, sealed heavy gauge aluminum box painted OSHA Yellow.
- Multiple output receptacles to accomodate several output loads simultaneously.
- Powers up immediately when plugged in.
- TEST and RESET push-buttons conveniently located on top to assure working condition.
- Ground fault starts buzzer beeping and removes output a.c. power from receptacles.
- Operating temperature: -35C to +66C (-31F to +149F).
- All semiconductor switching. No unreliable relay contacts to arc and weld together.
- Internal electronic over-current circuit removes output power if load current
exceeds rating.
- Designed to meet or exceed UL943 and CSA-22.2 No. 144-M91 saftey specs.
- Meets usage requirements defined by the National Electrical Code 2002 and OSHA.
- State-of-the-art high reliability design: single point component failures either remove output
voltage or do not prevent ground fault detection.
- US Pat. 6,804,094.
Electrical Specifications
- Input: 110 to 125 VAC, 120VAC nominal, 60 HZ, grounded neutral.
- Rated output current: 15 A. max. for Sandy Hook15; 20A. max. for Sandy Hook20.
- Power capability (continuous): 1800VA for Sandy Hook15; 2400VA for Sandy Hook20.
- Fault current: 6 ma. trip min. per UL493, Class A. Sharp cutoff
of faults less than 6 ma. prevents spurious (false) trips from
high leakage power tool cables. Fault current can be factory
adjusted for special values.
- Fault trip time: 2 - 16 millisec., relative to phase of input
a.c. sine wave at time of fault and size of fault current.
- Over-current protection: electronic sensing and shutdown.
No fuse or circuit breaker.
- RESET button clears both a fault and an over-current event,
allowing full 120VAC output to exist.
- 2 ft. input power cord with molded NEMA 5-15P, L5-15P, 5-20P, or L5-20P plug, depending on model.
Mechanical Specifications
- Outside dimensions: 5" H x 6" W x 9" L.
- Weight: 7 lbs.
- Enclosure is NEMA-3R; is sealed against rain (water resistant).
- Two dual or four single covered output receptacles: NEMA 5-15R, L5-15R, 5-20R or L5-20R, depending on model.
- Can be operated in any of 3 positions if required. Not designed for
permanent or post mounting. Portable only.
- Convection cooled; no internal fan.
Where to Buy it
For U.S. government agencies: Mar-Vel International    (A U.S. Gov't Prime Vendor Contractor)
7115 Airport Highway, Pennsauken, NJ 08109
Phone: 856/488-4499
Order phone: 800/325-5711 FAX: 856/488-4343
Web site
For all others: depress "CONTACTS" button.
Financial assistance for firefighting community
Funding grants are available to the firefighting community for assistance in the purchasing
of equipment needed for protection when using portable a.c. power and tools. Here are a few
suggested sites that can be used for grant application:
Federal: Dept. of Homeland Security
State of Pennsylvania: Office of State Fire Commissioner
(PA fire organizations only)
Fireman's Fund Heritage Grant
For a discussion as to why our GFCIs are superior to others, refer to the paper
The Need for High Reliability in GFCIs
in our Technical Papers section.